MAGNETIC CLAMPING SYSTEM
CONFIGURATION
TECHNICAL SPECIFICATIONS
Machine clamping Force in KN (TON) | ≤ 200 TON | > 200 TON |
Pole dimension | ø44 mm | ø66 mm |
Force/pole in DaN (kg) | 350 kg | 900 kg |
Plate Thickness (single) | 35 mm | 46 mm |
Max. working temperature | 120 / 150 / 180°C | 120 / 150 / 180°C |
Magnetic flux depth | 20 mm | 20 mm |
Proximity sensor range | 0,2 mm | 0,2 mm |
Standard voltages | AC230V/400V/415V/440V, 50/60Hz | AC230V/400V/415V/440V, 50/60Hz |
Ejector holes | Standard | Standard |
Centering rings | Standard | Standard |
Control unit | HQMC-11A/HQMC-12A | HQMC-11A/HQMC-12A |
Temperature sensor | Standard | Standard |
Proximity switch | Standard | Standard |
Magnetic flux sensor | Standard | Standard |
Die dislocation sensor | Standard | Standard |
Magnetic current detection | Standard | Standard |
Pole sealing | Metal | Metal |
Interface | EUROMAP 70.0/70.1 | EUROMAP 70.0/70.1 |
IMM 60 – 200 TON : Magnetic poles Ø 44 mm
IMM >200 TON : Magnetic poles Ø 66 mm
T1 = Max. temperature = 120°C
T2 = Max. temperature = 150°C
T3 = Max. temperature = 180°C
MOVABLE MAGNETIC PLATE

01
Eyebolt
02
Mounting holes
03
Mould dislocation Detection
04
Distance Detection
05
Magnetic Flux Detection
06
Junction Box
FIX MAGNETIC PLATE

01
Eyebolt
02
Mounting holes
03
Mould dislocation Detection
04
Location ring
05
Distance Detection
06
Magnetic Flux Detection
07
Temperature Detection
08
Junction Box