Electro Permanent LIFTING Magnets
Lifting of HEA-HEB-IPE-IPN-profiles
Electro permanent magnetic lifting system for manipulating profiles.
Electro permanent magnet modules with slim pole shoes for lifting profiles from 80-600 mm in lengths up to 24,000 mm
OPTIONAL: Turn able magnetic modules over 90° for profiles from 600 mm – 1000 mm.
Electronic control unit on board with selection of the magnetic modules, depending on the length of the profile to be lifted.
Control via the built-in digital push buttons or via the standard supplied radio remote control.
ELECTRO PERMANENT MAGNETIC TECHNOLOGY
The electric current is only used to invert the magnetic field, while the effective force is generated by permanent magnets. In the event of a power failure, the magnetic force remains permanently present = 100% safe
PICK-UP CYCLE
Lifting is done in 2 phases, whereby the workpiece is first lifted at a lower preset force, immediately followed by FULLMAG (100% of the total force)

SPC-SYSTEM (SYSTEM PERFORMANCE CHECK)
The electronic system continuously monitors the proper functioning of the magnet. Any abnormal situation is reported immediately and indicated by an error code on the help screen. In this way, errors can be immediately analysed and resolved.

SAFETY FACTOR 3:1
To lift safely, a possible air gap between the contact surface of the magnet, and the steel to be lifted, must be considered. That is why all our magnets are designed with a minimum safety factor of 3: 1 measured at an air gap of 0.4 mm.
2 BUTTON OPERATION
To start the demagnetization cycle, 2 buttons (SAFE + DEMAG) must be pressed consecutively on the remote control.
LAMP BLOCK
The status of the magnet is visually indicated by a clear LED lamp block. The load may only be moved when the green lamp lights up continuously!

LANDING DETECTION
An inductive proximity switch and associated cam, mounted on the harp shackle of the hoisting chain, prevents accidental demagnetizing in the air.
RADIO REMOTE CONTROL
The magnet is operated from a safe distance. The operator should not come in the immediate vicinity of the load.
INSTRUCTION PANEL
With clear safety instructions for the user regarding:
– Maximum weight of the load in function of material thickness
– Maximum wing in function of the deflection of the material.

Model | SWL (kg) | HEA-HEB-IPE-IPN | Length min - max (mm) | Qty EPM Modules | Weight (kg) |
---|---|---|---|---|---|
HS-06-013 | 1.300 | 80 - 600 | 1.000 - 6.000 | 2 | 500 |
HS-12-013 | 1.300 | 80 - 600 | 1.000 - 12.000 | 2 | 490 |
HS-12-026 | 2.600 | 80 - 600 | 500 - 12.500 | 4 | 900 |
HS-15-026 | 2.600 | 80 - 600 | 6.500 - 15.000 | 4 | 1.100 |
HS-18-039 | 3.900 | 80 - 600 | 500 - 12.500 | 6 | 1.400 |
HS-24-052 | 5.200 | 80 - 600 | 500 - 13.500 | 6 | 2.100 |