BATTERY POWERED ELECTRO PERMANENT MAGNETS

BATTERY POWERED ELECTRO PERMANENT MAGNETS

BATTERY POWERED - NO POWER SUPPLY CABLE NEEDED
HBEP

HBEP - Electro permanent lifting Magnets with Battery Supply

For safe lifting of flat and round workpieces. Equipped with AUTO function for fast unloading of cutting machines. Control via built-in digital push buttons or via the supplied radio remote control.

HBEPP-06-030L - gecomprimeerd

HBEPP - Battery powered Electro Permanent Magnetic Beam for steel Sheets

For efficient lifting of steel plates in various lengths from 5 mm thickness. Selection option of the magnetic modules, according to the length of the steel sheet.

IMG_20200813_105400_gecomprimeerd

HBEPS - Battery powered Electro Permanent Magnetic Beam for Profiles

Electro permanent magnetic beams for lifting IPE-IPN-HEA-HEB 80-600 profiles in lengths up to 24,000 mm. Integrated rechargeable battery group with high autonomy.​

The safest lifting Magnet

ELECTRO PERMANENT MAGNETIC TECHNOLOGY
The electric current is only used to invert the magnetic field, while the effective force is generated by permanent magnets. In the event of a power failure, the magnetic force remains permanently present = 100% safe

PICK-UP CYCLE
Lifting is done in 2 phases, whereby the workpiece is first lifted at a lower preset force, immediately followed by FULLMAG (100% of the total force)

SPC-SYSTEM (SYSTEM PERFORMANCE CHECK)
The electronic system continuously monitors the proper functioning of the magnet. Any abnormal situation is reported immediately and indicated by an error code on the help screen. In this way, errors can be immediately analysed and resolved. 

SPC-system

SAFETY FACTOR 3:1
To lift safely, a possible air gap between the contact surface of the magnet, and the steel to be lifted, must be considered. That is why all our magnets are designed with a minimum safety factor of 3: 1 measured at an air gap of 0.4 mm. 

2 BUTTON OPERATION
To start the demagnetization cycle, 2 buttons (SAFE + DEMAG) must be pressed consecutively on the remote control.

LAMP BLOCK
The status of the magnet is visually indicated by a clear LED lamp block. The load may only be moved when the green lamp lights up continuously!

LANDING DETECTION
An inductive proximity switch and associated cam, mounted on the harp shackle of the hoisting chain, prevents accidental demagnetizing in the air.

RADIO REMOTE CONTROL
The magnet is operated from a safe distance. The operator should not come in the immediate vicinity of the load.

INSTRUCTION PANEL
With clear safety instructions for the user regarding:
– Maximum weight of the load in function of material thickness
– Maximum wing in function of the deflection of the material.